4.4.1 Test panels and surface preparation. Unless otherwise specified (see 6.2), test panels shall be 150 by 150
by 3 millimeters (6 by 6 by 0.125 inch) cold rolled steel. Test panels shall be preconditioned by exposing the bare
metal panels to a salt fog spray for 100 hours in accordance with ASTM B117. Test panels shall then be wiped and
degreased in accordance with Method B, C, or D of ASTM D609. The degreased test panels shall be mechanically
cleaned in accordance with SSPC-SP 3 on both sides. For direct-to-metal underlayment systems (including all Type
III and Type IV products), the panels shall remain unprimed prior to application of the underlayment system. For
Type I or II underlayment systems requiring an anti-corrosive primer, the panels shall be primed with the primer
included by the manufacturer as part of the underlayment system, or with a primer conforming to MIL-DTL-
24441/20 or MIL-DTL-24441/29 if no specific primer is identified by the manufacturer.
4.5 Tests.
4.5.1 Toxicity. To determine conformance with the requirements of 3.5.1, the material shall be evaluated by
the Navy and Marine Corps Public Health Center using the administrative Health Hazard Assessment (HHA) (see
6.7).
4.5.1.1 Asbestos content. Asbestos content shall be determined on a dry film of the underlayment in
accordance with 29 CFR 1915.1001, Appendix K, Method ID-191, and the results shall be recorded as a percent by
weight of the dry underlayment film.
4.5.1.2 Soluble and total metal content. Soluble and total metal content, except tantalum and tungsten, shall be
determined on a dry paint film of the underlayment in accordance with 40 CFR 261, Appendix II, Method 1311, and
the appropriate test listed in Tables IV and V. Tantalum and tungsten soluble metal content and total metal content
shall be analyzed as specified in 4.5.1.2.1.
TABLE IV. Test methods for evaluating solid waste physical/chemical methods, EPA SW-846.
Metal/material
Digestion test method
All metals, except chromium (VI)
3050
Chromium (VI)
3060
Antimony
7040 or 7041
Arsenic
7060 or 7061
Barium
7080 or 7081
Cadmium
7131
Total chromium
7190
Chromium (VI)
7195, 7196, or 7197
Lead
7421
Mercury
7470 or 7471
Nickel
7520 or 7521
Selenium
7740 or 7741
Silver
7760 or 7761
TABLE V. Methods for chemical analysis of water and waste, EPA 600/4-79-020.
Metal/material
Test method
Beryllium
210.1 or 210.2
Cobalt
219.1 or 219.2
Copper
220.1 or 220.2
Fluoride
340.1, 340.2 or 340.3
Molybdenum
246.1 or 246.2
Thallium
279.1 or 279.2
Vanadium
286.1 or 286.2
Zinc
289.1 or 289.2